HX1225FNL / HX1225FNLT 100Base-T Ethernet MDL 1:1 TU Isolation Transformer

Spec Sheet Coming Soon

Email sales@bec.co.uk or call +44 (0) 1844 275824 for pricing and more information

SKU: HX1260FNL Category:

Description

Electrical Specifications @ 25°C

1.Turns Ratio:
(2-3):(15-14)=1CT:1CT

%%P2%P  (6-7):(11-10) =1.5CT:1CT  %%P2%P2.OCL:
200uH MIN @100KHz,0.1Vrms,at +25℃;
100uH MIN @100KHz,0.1Vrms,at -45℃;
100uH MIN @100KHz,0.1Vrms,at +95℃;
3.Isolation(Input- Output):
1650Vrms,6 Seconds MAX
4.Insertion Loss:
TX: 1-50MHz: -1.0dB MAX
RX: 1-50MHz: -1.5dB MAX
5.Return Loss(@100Ω):
TX: 0.5-40MHz: -18dB MIN
60MHz: -14.5dB MIN
80MHz: -12dB MIN
RX: 0.5MHz: -18dB MIN
40MHz: -10dB MIN
60MHz: -8dB MIN
80MHz: -6dB MIN
6.Cross Talk:
30MHz:  -45dB MIN
60MHz:  -35dB MIN
100MHz: -30dB MIN
7.Operating Temperature: 0℃~70℃/-40℃~+85℃